Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13670829

- Product Categories
- Friendly Links
Information Name: | Shore power battery brand distributor |
Published: | 2015-03-27 |
Validity: | 1000 |
Specifications: | 12V200AH |
Quantity: | 8000.00 |
Price Description: | |
Detailed Product Description: | Shore power battery brand distributor Beijing Xinyuan Hongyu Technology Co., Ltd. has the perfect pre-sale service of the system, the company has for many years engaged in the promotion of UPS and batteries and skill work force, can supply customers with consulting skills, skills serve a full range of seminars and maintenance, site planning, field devices. The company established the beginning, a "sincere and earnest operations, high-quality serve" as a place to live this. On the one hand the active development of the market, keeping up with the trend of the information industry to carry out, and constantly enhance the strength of the company's skills. Together vigorously strengthen internal management, improve the overall quality of employees, establish a good image of the company. "Pioneering innovation, seek excellence, career ahead, to serve the community," the company has long insisted thrust followed, carried out on the road constantly seeking, innovation, trade partner and work with all the new and old customers to create a boast Jiao tomorrow! Integrity - We uphold honesty, decency root, actually serve to provide users with the use of a battery charge and precautions shipped from the factory to the device used, the battery capacity will be subject to different degrees of loss, if the time is longer, before being put into use should be compensated charging. If the battery storage period does not exceed one year, at constant 2.27V / conditions only charge five days. If the battery storage period of 1 to 2 years, under constant 2.33V / Charging only five days. When the battery float use, make sure that each single battery float voltage is 2.25 ~ 2.30V, if the float voltage is above or below this size, the battery capacity will reduce life expectancy. When the battery float operation, the battery cell voltage should not be lower than 2.20V, such as the cell voltage is lower than 2.20V, you need to make a balanced charge. Balanced approach to charging: charging voltage 2.35V / only charging time 12 hours. When the battery cycle use after discharge selection of constant current limiting charging. A charging voltage of 2.35 ~ 2.45V / only, the maximum charging current less than 0.25C10 detailed way as follows: first with no more than the maximum current value of current of the constant current charging, the monomers to be charged to a uniform voltage to rise 2.35 ~ 2.45V when use uniform cell voltage is 2.35 ~ 2.45V voltage charge until the end of charge. Charging the battery completely symbolic cycle use: charging under constant conditions limiting the above, the symbol of a fully charged, it is possible in the following two optional one as discrimination based on: Charging time 18 to 24 hours (non-deep discharge time or shorter). Late Charge successive three hours charging current value does not change. 2.35 ~ 2.45V constant voltage charging, ambient temperature is a predetermined value of 25 ℃. When the ambient temperature is above 25 ℃, the charging voltage must be correspondingly reduced, to avoid the formation of overcharging. When the ambient temperature is below 25 ℃, the charging voltage should progress to avoid the charge deficiency. General decline or progress of ups and downs for each 1 ℃ change each monomer decrease 0.005V. ⒍ batteries recharged immediately after discharge, discharge the battery if the time is too long after the placement, even then can not recover its original charge capacity. When the battery use, it is necessary to tighten the screw terminals of the line immediately to avoid sparks and cause poor contact. When the battery is running to view and record battery put into operation, it should at least quarterly to measure the float voltage and open circuit voltage once, and for the record: each battery float voltage or open circuit voltage values ??monomer; terminal voltage of the battery system (total pressure); ambient temperature. Convergence should check once a year is not a loose wire and corrosion contamination appearance, loose wires and tighten the need for timely, joint erosion pollution timely for cleaning. Operation, such as found in the following unusual circumstances, it is timely to find fault reasons and replace battery problems: ⒍ voltage is abnormal; physical damage (shell, covered with cracks or deformation); battery fluid leaks; abnormal temperatures. |
Admin>>>
You are the 13827 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Xinyuan Hongyu Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 13827 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Xinyuan Hongyu Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility